Ion Meters

A130 Benchtop pH/Ion Meter

Professional pH and ion meter, 2 to 5 points calibration, setup menu contains 20 options. The meter is suitable for measuring the pH, mV, ion concentration and water hardness.

pH Mode:
• Professional pH/ion meter is equipped with a 7 inch TFT display.
• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
• Solution Temperature Coefficient compensates for the pure water samples and references
  the pH to 25°C.

Ion Meter

ORP Mode:
• 1 point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt modes ensure the reliable ORP measurements.

Ion Concentration Mode:
• 2 to 5 points calibration, including the 8 concentration points can be selected.
• Electrode management is capable of storing and recalling up to 3 electrode slopes.
• Selectable ion measurement methods (direct reading, known addition, known subtraction,
  sample addition, sample subtraction) and concentration units (ppm, mg/L, mol/L, mmol/L).

Water Hardness Mode:
• 2 to 5 points calibration from low to high concentrations.
• Selectable measurement units (german degree, english degree, french degree, mmol/L
  and mg/L) are used for professional water hardness measurements.

Ion Meter

Other Features:
• Automatic temperature compensation ensures accurate readings over the entire range.
• Auto-Read function senses and locks the measurement endpoint.
• Timed Interval Readings sends the measurement data to a PC or printer.
• Limit Alarm automatically alerts when reading exceeds the specified range.
• Calibration due alarm prompts user to calibrate the meter regularly.
• Calibration report shows the date, time, calibration points, slopes and offset.
• Password protection prevents the unauthorized calibration and settings.
• Expanded memory stores or recalls up to 1000 data sets.
• Reset function automatically resumes all settings back to the factory defaults.

   Model


A130

   pH



   Range


-2.000 to 20.000pH

   Resolution


0.001, 0.01pH, selectable

   Accuracy


±0.002pH

   Calibration Points


1 to 5 points

   pH Buffer Options


USA, NIST, DIN, 5 custom buffers

   ORP



   Range


±2000.0mV

   Resolution


0.1mV

   Accuracy


±0.2mV

   Calibration Points


1 point

   Measurement Modes


Relative or absolute mV

   Ion Concentration



   Range


0.001 to 30000 (deponding on the range of ISE)

   Resolution


0.001, 0.01, 0.1, 1

   Accuracy


±0.5% F.S. (monovalent), ±1% F.S. (divalent)

   Calibration Points


2 to 5 points

   Calibration Solutions

0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000

   Measurement Units


ppm, mg/L, mol/L, mmol/L

   Measurement Methods


Direct reading, known addition, known subtraction,


sample addition, sample subtraction

   Water Hardness



   Range (Concentration)


0.05 to 200mmol/L

   Range (German Degree)


0 to 1120°dH

   Range (English Degree)


0 to 1404°e

   Range (French Degree)


0 to 2000°fH

   Range (Ca2+)

0 to 8000mg/L

   Range (CaCO3)


0 to 19999mg/L

   Range (CaO)


0 to 11220mg/L

   Resolution


0.001, 0.01, 0.1, 1

   Accuracy

±1% F.S.

   Calibration Points

2 to 5 points

   Calibration Solutions

0.01, 0.1, 1, 10, 100mmol/L

   Temperature



   Range


0 to 105°C/32 to 221°F

   Resolution


0.1°C/0.1°F

   Accuracy


±0.5°C/±0.9°F

   Offset Calibration


1 point

   Calibration Range


Reading ±10°C

   General Specifications



   Temperature Compensation


0 to 100°C/32 to 212°F, manual or automatic

   Stability Criteria

Standard or high-accuracy

   Calibration Due Alarm

1 to 31 days or off

   Interval Readings

10, 30, 60 seconds, 10, 30 minutes or off

   Password Protection

4 digits

   Memory

Stores up to 1000 data sets

   Output

USB communication interface

   Connector

BNC, 3.5mm jack socket

   Display

7” TFT LCD

   Power

DC12V, using AC adapter, 220V/50Hz

   Dimensions

240(L)×220(W)×80(H)mm

   Weight

1.7kg

   Order Code

Accessories

   A130-CN

E201-BNC pH electrode

TP-10K temperature probe

pH4.01/7.00/10.01 buffer sachets

DC12V power adapter

   A130-UK

   

P11 glass pH electrode

TP-10K temperature probe

pH4.01/7.00/10.01 buffer sachets

DC12V power adapter

Items Description
P11 pH Electrode For the general applications
P11-LiCl pH Electrode For the non-aqueous samples
P11-HA pH Electrode For the high alkalines samples
P11-NA pH Electrode For the biofuels
P12 pH Electrode For the sample in the test tube
P13 pH Electrode For the micro-volume samples
P15 pH Electrode For the low conductivity samples
P16 pH Electrode For the Tris buffers
P18 pH Electrode For the slurries and soils
P19 pH Electrode For the semisolids
P21 pH Electrode For the colloids
P22 pH Electrode For the high temperature samples
501 ORP Electrode For the sample with strong redox potential
502 ORP Electrode For the sample with weak redox potential
Na-US Sodium Electrode Range: 0.1 to 23000ppm
CL-US Chloride Electrode Range: 1.8 to 35500ppm
F-US Fluoride Electrode Range: 0.02ppm to saturation
Ca-US Calcium Electrode Range: 0.02 to 4000ppm
NO3-US Nitrate Electrode Range: 0.4 to 62000ppm
Br-US Bromide Electrode Range: 0.4 to 79900ppm
NH4-US Ammonium Electrode Range: 0.1 to 18000ppm
Cn-US Cyanide Electrode Range: 0.2 to 260ppm
Cd-US Cadmium Electrode Range: 0.01 to 11200ppm
Cu-US Copper Electrode Range: 0.006 to 6400ppm
I-US Iodide Electrode Range: 0.06 to 127000ppm
Pb-US Lead Electrode Range: 0.2 to 20700ppm
Ag-US Silver Electrode Range: 0.01 to 107900ppm
K-US Potassium Electrode Range: 0.04 to 39000ppm
S-US Sulphide Electrode Range: 0.003 to 32100ppm
NH3-US Ammonia Electrode Range: 0.02 to 17000ppm
WH-UK Water Hardness Electrode Range: 0.05 to 200mmol/L
TP-10K Temperature Probe For the temperature measurement
pH Buffer Solutions 480ml/bottle
Ion Standard Solutions 480ml/bottle
Ionic Strength Adjuster 480ml/bottle
USB Cable For transferring data to PC
Thermal Printer For the A series meters

   Order Code

Carton Dimensions (L×W×H)

Weight    

   A130-CN

310×260×200mm

2kg    

   A130-UK

310×260×200mm

2kg